Index
visionCATS
4.1
  • What’s new in visionCATS 4.1
    • Changelog
      • visionCATS 4.1
        • Enhancements
        • Bug fixes
      • visionCATS 4.0
        • Enhancements
        • Breaking changes
        • Bug fixes
      • visionCATS 3.2 SP 2
        • Enhancements
        • Bug fix
      • visionCATS 3.2 SP 1
      • visionCATS 3.2
        • Enhancements
        • Breaking changes
        • Bug fixes
      • visionCATS 3.1
        • Enhancements
        • Bug fixes
      • visionCATS 3.0
        • Enhancements
        • Bug fixes
      • visionCATS 2.5
        • Enhancements
        • Bug fixes
    • Technology update
      • .NET
      • New Windows services
      • New comparison image format
    • CAMAG® Automatic Developing Chamber 3 (ADC 3)
      • CAMAG® HPTLC PRO Module APPLICATION
      • CAMAG® TLC Scanner 4
    • Profiles view in the impurity test
    • Evaluation
    • Spectrum Library Only with Spectrum Library option
    • Known Issues and workarounds
  • User documentation
    • Main window
      • Main Toolbar
        • Title bar
        • Main toolbar and menu
      • Software and instruments help
        • Software
        • Instrument manuals
        • About visionCATS
      • Toolboxes
        • Instruments Toolbox
        • System Log Toolbox
      • System Status Bar
        • Last system log entry
        • HPTLC PRO SYSTEM status
        • Selection of the HPTLC PRO SYSTEM
        • Selected HPTLC PRO SYSTEM status
        • Login of current user
        • Name of the visionCATS server and status of all instrument services:
        • Used memory by the client
    • File Explorer
      • Main explorer view
        • 1.Contents of the current folder
        • 1. Navigation
        • 3. History
        • 4. Status bar
        • 5. Sort options
        • 6. Search options
          • Default textual search
          • Simple search shortcuts
          • Advanced search
            • Building search queries
            • Configuring the default search
            • Defining user queries
      • Preview view
      • File Types
        • Folders
        • Methods
        • Analysis
        • winCATS Analysis
        • Comparison
      • File Status
      • File Actions
        • Menu New
        • Menu File
        • Menu Edit
        • Menu Tags
      • Exchanging files with other visionCATS installations
        • Importing
          • Unsupported data
        • Exporting
    • Vials management
      • Vial ID naming
      • Reuse of vial
      • Additional vials management features
    • Method / Analysis File
      • HPTLC Steps
      • Chromatography
        • Track Assignment
          • Overview
          • Description of fields
          • Display
          • Keyboard navigation
          • Import/export functions
            • Options and formats
            • Fields and checks
            • Tracks import preview
        • Instrument step parameters
          • Plate Layout
            • Plate Manufacturer
            • Stationary Phase
            • Batch Number
            • Plate Format
            • Application Type
              • Application Position Y [mm]
              • First Application Position X [mm]
              • Track Distance [mm]
              • Application Length [mm]
              • Application Width
            • Solvent Front Position [mm]
          • CAMAG® HPTLC PRO Module APPLICATION
          • ATS 4
            • Sample Solvent Type
              • Equivalent Solvents
              • Dosage Speed [nL/s]
              • Pre-Dosage Volume [nL]
              • Filling Speed [µL/s]
              • Filling Vacuum Time [s]
              • Retraction Volume [nL]
              • Rinsing Vacuum Time [s]
            • Filling/Rinsing Quality
              • Rinsing Solvent
              • Rinsing Cycles
              • Do Not Rinse Before Next Vial
              • Empty Syringe Before Next Vial
              • Flush nozzle
              • Filling cycles
              • Fill Only Programmed Volume
              • Return Unused Sample into Vial
              • Syringe Volume [µL]
              • Spray Gas:
            • Rack Type
              • Vial Bottom Level [mm]
            • Nozzle Heating
              • Temperature Settings
          • Linomat 5
            • Sample Solvent Type
              • Equivalent Solvents
              • Dosage Speed [nL/s]
              • Pre-Dosage Volume [nL]
          • Manual application
          • CAMAG® HPTLC PRO Module DEVELOPMENT
          • ADC 2
          • ADC 3
          • AMD 2
          • Chamber
          • CAMAG® HPTLC PRO Module DERIVATIZATION
          • Derivatizer
          • Immersion
          • Spraying
          • TLC Visualizer
          • TLC Scanner 4
            • Scanner Type
            • Optimization For
            • Measurement Mode
            • Detector Mode
            • Speed/Resolution/Slit
              • Scanning Speed
              • Data Resolution
              • Slit
              • Partial Scan
            • Wavelength Selection
              • Lamp
              • Wavelength(s) Applied
            • Spectrum Parameters
              • Reference Spectrum
              • Purity
              • Lamp
            • Profile Representation
          • Common features
        • Instrument step execution
          • Instruction display
            • HPTLC PRO
          • Execution display
            • Common progression display
            • Closing analysis during execution
            • Application steps
            • Development steps
              • ADC 3
            • Data acquisition steps
              • TLC Visualizer
              • TLC Scanner 4
              • HPTLC PRO
          • Analyses recovery
        • Multiple application steps
        • Multiple development steps
        • Extended Linearity
      • Data View
        • Images View
          • DataView Toolbar
            • General tools
            • Export tool
            • 𝑅ꜰ Tools and Tracks
            • Image Settings
              • HDRI Settings
            • Annotations
        • Tracks View
        • Profiles View
      • Spectrum
        • Positioning
          • Overview
          • Spectrum Definition Table
          • Substance Positioning
        • Execution
        • Data
          • Overview
          • Spectrum Scan View
            • Display
            • Toolbar
            • Purity
            • Correlation
            • Maximums
            • Spectrum Library Only with Spectrum Library option
        • Correlation
          • Overview
          • Spectrum Correlation Data
      • System Suitability Testing (SST)
        • SST Table
          • Toolbar
        • Overview
        • SST View
      • Impurity test
        • Checks
          • Toolbar
          • Check computation
        • Tracks view
          • Overview
          • Data View
        • Profiles view
          • Overview
          • Data View
      • Evaluation
        • Evaluation steps
          • Definition
            • Overview
            • Substance Table
              • Advanced options
            • References
            • Samples
          • Integration
            • Overview
            • Peaks table
            • Profiles view
            • Integration tools
              • Bounds
              • Smoothing
              • Baseline
              • Profile Subtraction
              • Peaks
          • Substance assignment
            • Substances table
            • Profiles view
            • Substances view
            • Tracks view
            • Toolbar
          • Calibration
            • Overview
            • Height/Area views
            • Calibration function view
          • Results
            • Overview
            • Main results
              • Main display
              • Configuring the display
              • Limit tests
              • Sample reference amount display
            • Substances groups
              • Overview
              • Definition
              • Display
        • Advanced options
          • Related Substances
            • Overview
            • Defining main and related substances
            • During the calibration
            • In the results
          • Internal Standard
            • Overview
            • Defining the Internal Standard
            • During the calibration
            • In the results
          • Standard for error correction
            • Overview
            • Defining the standard for error correction
            • During the calibration
            • In the results
          • Reproducibility
            • Overview
            • During the definition
            • In the results
          • Assignment mode
            • Overview
            • Multiple assignment mode
              • Integration phase
              • Substance assignment phase
              • Calibration phase
              • Results phase
            • Range assignment mode
              • Integration phase
              • Substance assignment phase
              • Calibration and results phases
          • LOD / LOQ
            • Overview
            • Defining LOD/LOQ
            • Calibration and results
              • USP mode
              • LOD checks
              • LOQ checks
        • Calibration computations
          • Concepts and common values
            • Regression functions
            • Regression range
            • Computation of the analysis points
            • Coefficient of variation of the calibration function
            • Correlation coefficient of the calibration function
            • Coefficient of variation of the sample results
          • Computation of the calibration functions
            • Linear-1
              • Calibration function
              • Regression
            • Linear-2
              • Calibration function
              • Regression
            • Polynomial
              • Calibration function
              • Regression
            • Mime-1 and Mime-2
              • Principles
              • Starting point
              • Calibration function
              • Regression
        • Evaluation assistant
      • Remarks
        • Editing features
        • Limitations
      • Report
        • Report Settings
          • Report template selection
          • Report template options
          • Tracks data options
          • Data acquisition options
          • Image display options
          • Evaluation options
          • Log options
        • Outline
        • Preview
        • Method report
      • Log
      • Export of data
        • Peaks table export
        • Substance assignment export
        • Evaluation results export
        • Profile data export Only with Export data option
        • Raw profiles export Only with Export data option
        • Integrated profiles export Only with Export data option
        • Comparison profiles export Only with Export data option
        • Spectrum export Only with Export data option
        • Analysis spectrum data export Only with Export data option
        • Comparison spectrum export Only with Export data option
    • Comparison Viewer
      • Overview
        • How it works
        • Common functionalities
      • Export to comparison
        • Overview
        • Images and profiles export to comparison
        • Spectrum export to comparison
      • Image comparison
        • Display
        • Overview
        • Illumination selection
        • Toolbar
        • Track information
        • Image format
      • Profile comparison
        • Tracks view
          • Display
            • Overlay
            • Stack
          • Overview
          • Wavelength or illumination selection
          • Toolbar
          • Tools
          • Profile selection
            • Profile selection toolbar
            • Profile selection lists
        • Wavelengths view
      • Spectrum comparison
        • Display
        • Overview
        • Spectra to display
        • Toolbar
        • Maximums
        • Spectrum definition selection
      • Remarks
      • Report
        • Report template selection
        • Report settings
          • Global settings
          • Image settings
          • Profile settings
          • Spectrum settings
      • Log
    • Tools
      • Toolboxes
      • Other tools
        • Vial/Substance Editor
          • Vial List
          • Substance List
          • Selected Vial
          • Selected Substance
          • Substance in Vial
          • Bulk editing
        • Global lists editor
          • Global list items management
          • Toolbar
          • Used in section
          • Naming checks
            • Adding and renaming items
            • Global list items formatting
            • Global list items display configuration
          • Migration from visionCATS 3.2
            • Updated built-in Items (old name -> new name)
            • New global list Known chemicals
            • Files import
            • Handling of duplicates
    • Administration / Options
      • User Management
        • Users and groups rights
        • Users
          • Toolbar
          • User table
            • Tooltips
        • Groups
          • Toolbar
            • New group
      • General Settings
        • Installations
          • Toolbar
          • Main installation table
        • COM Ports
          • Toolbar
        • USB Ports
          • Toolbar
        • Instruments Configuration
        • Global Configuration
          • Analysis
            • Exposure normalization for images
            • Exposure normalization range on track
            • TLC Visualizer 2/3 use the same reference point as a TLC Scanner 3/4
            • TLC Visualizer (any version) use a smaller ROI for auto exposure
            • TLC Visualizer (any version) max. exposure time for HDRI images
          • User management
          • Notifications
          • Global Lists
      • User Options
        • Miscellaneous
          • Explorer options
          • Method and analysis options
          • Dialogs options
          • CSV export options
        • Notifications
      • Report Settings
        • Reports Configuration
          • Reports header logo
          • Reports page setup
          • Global CSS
        • Report templates
        • Report templating
          • Technologies
            • HTML
            • CSS
              • Colors
              • SCSS
            • JavaScript
              • Handlebars
              • linq.js
              • D3.js
              • Flot (legacy)
              • Other JavaScript libraries
            • EO.Pdf
          • Breaking changes
            • visionCATS 4.1
              • SCSS files
            • visionCATS 4.0
              • JSON
              • Report data
              • SCSS files
            • visionCATS 3.2
              • Evaluation results
            • visionCATS 3.1
              • CSS files
              • Libraries changes
              • Rendering changes
              • D3.js replacing Flot
              • JavaScript version
              • HTML changes
            • visionCATS 3.0
              • New instrument names
            • visionCATS 2.5
              • Unit converter functions
              • Sample reference amount
          • Versioning
          • Debugging the report template
            • PDF generation debug
            • PDF generation temporary folder
              • Report temporary files structure
            • Debugging tools
              • Web browser developer tools
              • Code editor
          • Changing template styles
            • Global and template specific styles
            • Tutorials
              • Changing the global styles
              • Overriding global styles for a specific template
          • Changing template structure
            • General structure
            • Heading and report overview
            • Tutorials
              • Simple re-ordering and visibility
              • Header logo only on the first page
              • New layout
              • Displaying only log of a specific type
              • Bullet graph for limit tests
    • Profiles viewer
      • Axis
      • Navigation in 2D
        • Zooming the view
          • One axis zooming
        • Panning the view
      • Navigation in 3D
        • Zooming the view
        • Panning the view
        • Rotating the view
      • Viewing modes
      • Export
    • HPTLC PRO
      • Overview
        • Terminology
        • Status colors
          • CAMAG® HPTLC PRO SYSTEM status
          • HPTLC PRO Module status
        • Conveyor Manager
      • Configuration
        • Setup
        • HPTLC PRO Settings
          • CAMAG® HPTLC PRO SYSTEM Configuration
            • Main toolbar
            • HPTLC PRO SYSTEM row
            • HPTLC PRO SYSTEM toolbar
        • HPTLC PRO Module
          • Properties tab
          • Manual control tab
            • CAMAG® HPTLC PRO Module PLATE STORAGE
            • CAMAG® HPTLC PRO Module APPLICATION
            • CAMAG® HPTLC PRO Module DEVELOPMENT
            • CAMAG® HPTLC PRO Module DERIVATIZATION
          • Diagnostics tab
          • Operations tab
          • Firmware tab
        • CAMAG® HPTLC PRO SYSTEM Details
          • Display
          • History tab
          • Manual control tab
          • Diagnostics tab
            • With CAMAG® HPTLC PRO Module PLATE STORAGE
      • Execution
        • Typical execution
        • Preparation
          • Analysis splitting in HPTLC/TLC steps and HPTLC PRO runs
          • Multiple CAMAG® HPTLC PRO Module APPLICATION steps in an analysis
        • Execution
          • Display Tab overview
            • Toolbar
            • Modules
            • Status
            • Sequences
          • Consumables validation
            • Consumables check
              • Vial position in HPTLC PRO Module APPLICATION rack
          • Execution of a sequence
            • Using an CAMAG® HPTLC PRO SYSTEM without any CAMAG® HPTLC PRO Module PLATE STORAGE
            • Using an HPTLC PRO SYSTEM with a CAMAG® HPTLC PRO Module PLATE STORAGE
          • Last sequence info
          • History tab
            • Functionalities
            • Table display mode
            • Types of elements
            • Groups
            • Event categories
            • Action categories
            • Severity
        • Troubleshooting
          • Cases
          • Troubleshooting functions
            • HPTLC PRO SYSTEM reinit
            • HPTLC PRO Module reset
            • HPTLC PRO SYSTEM reset
      • Advanced
        • Understanding the HPTLC PRO Module and CAMAG® HPTLC PRO SYSTEM initialization
    • 21CFR Part 11 compliance
      • Understanding the logging features
      • System logger
      • HPTLC Logger
      • Deletion of data
        • Files and folders archiving
        • Steps data loss and steps reexecution
      • Motivated change
      • Open as management
      • E-Signature
      • Data integrity
        • How to setup Windows user rights for data integrity
  • Installation and support
    • Introduction
      • Architecture
      • Editions and options
      • End user license information
    • Installation
      • Parts supplied
        • Content of the visionCATS installation media
      • PC System Requirements
        • System Requirements
        • Installation Drive
        • Communication ports
        • Supported operating systems
          • Needed software
        • Network
        • Color quality
        • System printer (optional)
        • Additional software installed
      • Installation procedure
        • Post installation
      • Troubleshooting
      • Post Installation
        • Graphics performance preference
        • Disable Fast startup
        • Disable Windows hibernation and sleep modes
        • Disable USB selective suspend setting
        • Inform users to close visionCATS before locking the session
      • Installation of USB to RS232 adapter
        • Troubleshooting for RS232 adapter
      • Installation of TLC Visualizer 2/3 camera
        • Camera driver installation
      • Installation of HPTLC PRO drivers
        • USB Driver
          • Automatic installation by Windows Update
          • Manual installation
          • Installation end
        • DFU Driver
      • Update of TLC/HPTLC instrument firmware
        • For instruments with RS232 connection
      • Update of HPTLC PRO Module firmware
      • Update of HPTLC USB instrument firmware
    • Licensing
      • General information
      • Activation
      • Upgrades
        • Re-activating your existing license
      • Hardware changes
    • Client profiles
    • Instrument diagnostics
      • Diagnostics expiration for HPTLC PRO Module
      • Diagnostics view
      • How to do the diagnostics
    • visionCATS Diagnostics
      • Properties
      • Client Diagnostics
    • Backup / Restore
      • Backup procedure for visionCATS
      • Restore procedure for visionCATS
      • Scheduling backup
        • Automatic backup
        • Manual backup
          • Configure network share for scheduled backup
            • Network architecture
            • Setting backup folder
            • Creating the network share with correct rights
            • Setting backup folder: retry
    • Instrument Properties
    • Maintenance and troubleshooting
      • General maintenance
      • Service Tool
    • Known Issues and Workarounds
      • Troubleshooting USB connection errors for HPTLC PRO Modules or new HPTLC instruments
    • Logging
      • Installer logs
      • visionCATS logs available
      • The Get debug logs functionality
  • visionCATS Guide
    • General Introduction
      • The visionCATS concept: HPTLC made easy!
      • Key features
      • Benefits
    • Getting Started
      • Main window
      • Folders
    • Create a method
      • Working with methods that comply with USP and Ph. Eur.
      • Working with methods from the Method Library
      • Create a new method from scratch
    • Execute an analysis
      • Performing a method transfer validation
      • Setting the analysis
    • Data view
      • Data type
      • Overview
      • Toolbar
      • Remarks, report, log
      • Relevant tools
      • Export of Images
    • Working with SST
    • Scanning Densitometry
      • Single-wavelength scan
      • Multi-wavelength scan
    • Peak profile from images (PPI)
    • Evaluation
      • Basics of quantitative evaluation in visionCATS
      • Manual mode
      • Expert mode
      • Peak table export
      • Related substances
      • Standard for error correction
      • Reproducibility
      • Limit test
      • Export results
      • Export graphs
    • Spectrum Scan
    • Working with Comparison files
      • Image Comparison
      • Profile Comparison
      • Spectrum Comparison
    • Other features
      • Quick scan / Partial scan
      • Dual Wavelength scan and (blank) track subtraction
      • AMD 2 settings
    • Reports
    • Export of Data
    • 21 CFR Part 11
    • Example Files
    • Case studies with application tutorial videos
      • HPTLC-Fingerprint of Ginkgo biloba flavonoids (qualitative example)
      • Identification of fixed oils by HPTLC (qualitative example, including method transfer validation)
      • In-process control during chemical synthesis (qualitative example, including HPTLC-MS)
      • Quantitative determination of steviol glycosides (quantitative example)
  • Glossary
visionCATS
  • User documentation
  • Administration / Options
  • Report Settings
  • Report templating

Report templating

  • Technologies
    • HTML
    • CSS
      • Colors
      • SCSS
    • JavaScript
      • Handlebars
      • linq.js
      • D3.js
      • Flot (legacy)
      • Other JavaScript libraries
    • EO.Pdf
  • Breaking changes
    • visionCATS 4.1
      • SCSS files
    • visionCATS 4.0
      • JSON
      • Report data
      • SCSS files
    • visionCATS 3.2
      • Evaluation results
    • visionCATS 3.1
      • CSS files
      • Libraries changes
      • Rendering changes
      • D3.js replacing Flot
      • JavaScript version
      • HTML changes
    • visionCATS 3.0
      • New instrument names
    • visionCATS 2.5
      • Unit converter functions
      • Sample reference amount
  • Versioning
  • Debugging the report template
    • PDF generation debug
    • PDF generation temporary folder
      • Report temporary files structure
    • Debugging tools
      • Web browser developer tools
      • Code editor
  • Changing template styles
    • Global and template specific styles
    • Tutorials
      • Changing the global styles
      • Overriding global styles for a specific template
  • Changing template structure
    • General structure
    • Heading and report overview
    • Tutorials
      • Simple re-ordering and visibility
      • Header logo only on the first page
      • New layout
      • Displaying only log of a specific type
      • Bullet graph for limit tests
Previous Next

© Copyright 2025, CAMAG. Last updated on Feb 21, 2025.

visionCATS version: 4.1
Versions
2.5
3.0
3.1
3.2
4.0
4.1