Index
visionCATS
2.5
  • Introduction
    • Architecture
    • Editions and options
    • End user license information
  • What’s new in visionCATS 2.5
    • Changelog
      • visionCATS 2.5
        • Enhancements
        • Bug fixes
      • visionCATS 2.4
        • Enhancements
      • visionCATS 2.3 SP1
        • Enhancements
        • Bug fixes
      • visionCATS 2.3
        • Enhancements
      • visionCATS 2.2
        • Enhancements
      • visionCATS 2.1
        • Enhancements
        • Bug fixes
      • visionCATS 2.0 SP2
        • Bug fixes
      • visionCATS 2.0 SP1
        • Bug fixes
      • visionCATS 2.0
        • Enhancements
      • visionCATS 1.4 SP2
        • Bug fixes
      • visionCATS 1.4 SP1
        • Bug fixes
      • visionCATS 1.4
        • Enhancements
      • visionCATS 1.3
    • Improved search in Explorer
    • Instruments
      • Improved HDRI for HPTLC Visualizer 2
    • New concentration unit type choices
    • Analysis and Comparison Profile Wavelength view
      • In Analysis
      • In Comparison Profile
    • Peak detection in Comparison Profile
    • HPTLC log in report
    • Open as
    • Notifications on analysis progress
    • Profile viewer with docking or multi windows
    • visionCATS Diagnostics
  • Installation
    • Parts supplied
      • Content of the visionCATS installation disc
    • PC System Requirements
      • System Requirements
      • Installation Drive
      • Communication ports
      • Supported operating systems
      • Color quality
      • System printer (optional)
      • Additional software installed
    • Installation procedure
    • Installation of USB to RS232 adapter
      • Troubleshooting for RS232 adapter
    • Installation of TLC Visualizer camera
      • OHCI driver installation
      • Camera driver installation
      • Configuration for Windows 10
    • Installation of TLC Visualizer 2 camera
      • Camera driver installation
    • Update of instrument firmware
      • For instruments with RS232 connection
      • For the camera of TLC Visualizer
  • Main window
    • Main Toolbar
    • Toolboxes
      • Project Explorer Toolbox
      • Instruments Toolbox
      • System Log Toolbox
    • System Status Bar
  • File Explorer
    • Main explorer view
      • 1.Contents of the current folder
      • 2. Navigation
      • 3. History
      • 4. Status bar
      • 5. Sort options
      • 6. Search options
        • Default textual search
        • Simple search shortcuts
        • Advanced search
    • Preview view
    • File Types
    • File Status
    • File Actions
      • Menu New
      • Menu File
      • Menu Edit
      • Menu Tags
  • Method / Analysis File
    • HPTLC Steps
    • Chromatography
      • Sample Sequence
      • Instrument step parameters
        • Plate Layout
        • ATS 4
        • Linomat 5
        • Nanomat
        • ADC 2
        • AMD 2
        • Chamber
        • Derivatization dip
        • Derivatization spray
        • Derivatizer
        • Visualizer/Visualizer 2
        • Scanner 4
        • Scanner 3
      • Instrument step execution
        • Instruction display
        • Execution display
          • Visualizer/Visualizer 2
          • Scanner 3/Scanner 4
    • Data View
      • Images View
        • DataView Toolbar
          • General tools
          • RF Tools and Tracks
          • Image Settings
            • HDRI Settings
          • Annotations
      • Tracks View
      • Profiles View
    • Spectrum
      • Positioning
        • Overview
        • Spectrum Definition Table
        • Substance Positioning
      • Execution
      • Data
        • Overview
        • Spectrum Scan View
          • Display
          • Toolbar
          • Purity
          • Correlation
          • Maximums
      • Correlation
        • Overview
        • Spectrum Correlation Data
    • System Suitability Testing (SST)
      • SST Table
      • Overview
      • SST View
    • Evaluation
      • Definition
        • Sequence
        • Substance Table
        • References
        • Samples
      • Integration
        • Overview
        • Peaks table
        • Profiles view
        • Integration tools
          • Bounds
          • Smoothing
          • Baseline
          • Profile Subtraction
          • Peaks
            • Interactive baseline
              • Toolbar
              • Baseline segments list
              • Spline type
            • Manual peak edition
              • Peak’s start and end edition
      • Substance assignment
        • Substances table
        • Profiles view
        • Substances view
        • Tracks view
        • Toolbar
      • Calibration
        • Overview
        • Height/Area views
        • Calibration function view
      • Results
      • Related Substances
        • Overview
        • Defining main and related substances
        • During the calibration
        • In the results
      • Internal standard
        • Overview
        • Defining the internal standard
        • During the calibration
        • In the results
      • Reproducibility
        • Overview
        • During the definition
        • In the results
      • Limit Test
        • Overview
        • During the definition
        • In the results
    • Remarks
      • Editing features
      • Limitations
    • Report
      • Report Settings
        • Report template selection
        • Report template options
        • Tracks data options
        • Data acquisition options
        • Image display options
        • Evaluation options
        • Log options
      • Outline
      • Preview
    • Log
    • Profiles viewer
      • Axis
      • Navigation in 2D
        • Zooming the view
          • One axis zooming
        • Panning the view
      • Navigation in 3D
        • Zooming the view
        • Panning the view
        • Rotating the view
      • Viewing modes
      • Export
    • Export of data
      • Peaks table export
      • Substance assignment export
      • Evaluation results export
      • Profile data export
        • Raw profiles export
        • Integrated profiles export
        • Comparison profiles export
      • Spectrum export
        • Analysis spectrum data export
        • Comparison spectrum export
  • Comparison Tool
    • Overview
      • How it works
      • Common functionalities
    • Export to comparison
      • Overview
      • Images and profiles export to comparison
      • Spectrum export to comparison
    • Image comparison
      • Display
      • Overview
      • Illumination selection
      • Toolbar
      • Track information
    • Profile comparison
      • Tracks view
        • Display
          • Overlay
          • Stack
        • Overview
        • Wavelength or illumination selection
        • Toolbar
        • Tools
        • Profile selection
          • Profile selection’s toolbar
          • Profile selection’s lists
      • Wavelengths view
    • Spectrum comparison
      • Display
      • Overview
      • Spectra to display
      • Toolbar
      • Maximums
      • Spectrum definition selection
    • Remarks
    • Report
      • Report template selection
      • Report settings
        • Global settings
        • Image settings
        • Profile settings
        • Spectrum settings
    • Log
  • Tools
    • Vial/Substance Editor
      • Vial List
      • Substance List
      • Selected Vial
      • Selected Substance
      • Substance in Vial
    • Method Library
      • Downloading and using CAMAG Methods
      • Download by using the Standalone Downloader
      • Method deployment
      • Additional features
  • Administration / Options
    • Licensing
      • General information
      • Activation
      • Upgrades
        • Re-activating your existing license
    • 21CFR Part 11 compliance
      • Understanding the logging features
      • System logger
      • HPTLC Logger
      • Data deletion
      • Motivated change
      • Open as management
      • E-Signature
      • Data integrity
        • How to setup Windows user rights for data integrity
    • User Management
      • System Settings
      • Users
        • Toolbar
        • User table
    • visionCATS Diagnostics
      • Properties
      • Client Diagnostics
        • Diagnostics
          • How to do the diagnostics
    • Instrument Properties
    • Instrument IQ/OQ
    • General Settings
      • Installations Configuration
        • Toolbar
        • Server Installation
        • Client installations
        • Instrument Service with Client Installations
        • Client only Installations
        • Manage Instrument Service
        • Manage Client only
      • Instruments Configuration
      • Global Configuration
        • Analysis
        • Step parameters global lists
        • Notifications
      • Reports Configuration
        • Reports header logo
        • Reports page setup
        • Global CSS
        • Report templates
    • Display Options
      • Method and analysis options
      • Dialogs options
      • CSV export options
    • Report templating
      • Technologies
        • HTML
        • CSS
          • Colors
          • SCSS
        • JavaScript
          • Handlebars
          • linq.js
          • Flot
          • SignalR and Metamorph
          • Other JavaScript libraries
        • wkhtmltopdf
      • Breaking changes
        • visionCATS 2.5
          • Unit converter functions
          • Sample reference amount
      • Versioning
      • Debugging the report template
        • PDF generation debug
        • PDF generation temporary folder
          • Report temporary files structure
        • Debugging tools
          • Web browser’s developer tools
          • Code editor
      • Changing template styles
        • Global and template specific styles
        • Tutorials
          • Changing the global styles
          • Overriding global styles for a specific template
      • Changing template structure
        • General structure
        • Heading and report overview
        • Tutorials
          • Simple re-ordering and visibility
          • Header logo only on the first page
          • New layout
          • Displaying only log of a specific type
            • Simple filter
            • Filtering and only the motivated text
  • Maintenance and troubleshooting
    • General maintenance
    • Service Tool
    • Known Issues and Workarounds
  • Backup / Restore
    • Backup procedure for visionCATS
    • Restore procedure for visionCATS
    • Scheduling backup
      • Automatic backup
      • Manual backup
        • Configure network share for scheduled backup
          • Network architecture
          • Setting backup folder
          • Creating the network share with correct rights
          • Setting backup folder: retry
  • Glossary
visionCATS
  • »
  • Method / Analysis File »
  • Evaluation »
  • Related Substances

Related Substances¶

Overview¶

The Related Substances functionality allows you to calibrate a substance of an evaluation with the calibration curve of another substance. A typical use case consists in the quantification of impurities in drug substances. The Main substance is the main component of the drug while each impurity is a Related substance. In order to confirm that the related substances are impurities, the sum of their quantities must not exceed a defined limit (normally 2% of the main substance). Therefore the typical workflow consists in:

  • Quantifying the main substance at an appropriate set of concentration/volume applied,

  • Quantifying the related substances at an appropriate set of concentration/volume applied, normally smaller than the set used for the main substance, and

  • Using the calibration curve of the main substance for the calibration of the related substances.

Defining main and related substances¶

../../_images/related_substances_definition.png

In the evaluation’s Definition tab, use the Advanced options button to make the Related substances field appear. In an evaluation, there can be only one Main substance, other substances can be of type Related substances or Default. Of course, the functionality will only work if the main substance and at least one related substance are defined. Because the related substances use the calibration curve of the main substance, the calibration-related fields are hidden for related substances.

The related substance functionality can be used in 3 modes, accessible by clicking on the Related substances parameters button :

  • Default: this is the simplest and the most generic mode, already present in winCATS, where only the substitution of the calibration curve is done for each related substance. This mode offers the most freedom but gives only the normal results of the quantification. The 2 other modes include the Allowed impurity amount field which enables the computation of the sum of impurities for each track.

  • By dilution: use this mode when a vial defined as Sample in the evaluation has been diluted (one or many times). Each dilution gives its own vial ID defined as Reference in the evaluation. In the configuration of this mode:

../../_images/related_substances_dilution.png

The Sample to use as reference concentration field has to be filled and the corresponding sample’s Amount and Volume solution in the Samples section have to be defined.

../../_images/related_substances_dilution_sample.png

The Amount and Volume solution fields give a reference concentration, and the volume applied has to be the same for all applications of this sample, therefore, there’s a reference quantity too, which will be used when computing the results of the evaluation. In the References section, once the reference concentration is defined, the dilution factor can be directly entered instead of the concentration, and the tooltip explains the correspondance between the dilution factor and the actual concentration:

../../_images/related_substances_dilution_reference.png

  • By volume: use this mode when the same vial is used on many reference tracks in the evaluation at different volumes. A correspondance between one of those reference application and the known amount of impurities (in %) has to be defined:

../../_images/related_substances_volume.png

Similar to the By dilution mode, this configuraction actually gives a reference quantity which will be used as a basis to compute the results in percentage.

During the calibration¶

During the Calibration phase, the sample points are not computed for the main substance. Indeed, the goal is to quantify the related substances. When a related substance is displayed:

  • The calibration configuration on top of the view is not modifiable and shows the calibration data of the main substance

  • An information text recalls the main substance

  • The tooltip on a reference or sample calibration point shows the additional relative quantity computed (only in By dilution and By volume modes)

  • The x-axis is expressed in percentage (only in By dilution and By volume modes)

../../_images/related_substances_calibration.png

In the results¶

In the Results tab, the results are not displayed for the main substance of the evaluation. When the By dilution or the By volume mode is selected, a Related substances tab appears. It displays, for each track, the details of the related substances percentages. In order to confirm that the related substances are impurities, the Status field indicates whether some tracks exceed the allowed impurity amount.

Use the Export results (CSV) button to get a flattened table of the related substances results useful for future processing.

../../_images/related_substances_results.png
Previous Next

© Copyright 2022, CAMAG. Last updated on Feb 21, 2025.

visionCATS version: 2.5
Versions
2.5
3.0
3.1
3.2
4.0
4.1